HEALTH & SAFETY INFORMATION
1. IDENTIFICATION
XD2 AND XD2/DM DEVELOPER REPLENISHERS
Concentrated photographic developers designed for rapid processing X-ray machines. Each case of XD2 makes 2x20 litres of working strength solution on diluting with water. XD2/DM is the same product but packed especially for the Dupont chemical mixer, making up 40 litres.
XD2 comprises three different solutions – Parts A, B and C – packed together in plastic bottles in a cardboard box, each in duplicate. XD2/DM has single Part B and C bottles but twin Part A’s.
XD2
Part A - 2x5 litres
Part B - 2x500ml
Part C - 2x500ml
XD2/DM
Part A - 2x5 litres
Part B - 1 x 1 litre
Part C - 1 x 1 litre
The Packing Code is 4G for both products.
The product is manufactured by Photosol at the above address.
In emergency, telephone +44 (0)1268 293612 in business hours, or +44 (0)1277 810351 at other times.
2. COMPOSITION
Major components are as follows. These include those defined as hazardous to health in the Control of Substances Hazardous to Health Regulations, i.e. appear in the Chemicals (Hazard Information & Packaging) (CHIP) Regulations &/or which have a maximum exposure limit or occupational exposure standard in the Health & Safety Executive document EH40. These regulations are themselves based on EC Directives of which 88/379/EEC, 67/548/EEC & 91/325/EEC are particularly relevant.
| Component | CAS No. | % w/w | Symbol | Risk Phrase |
| | | | | |
| Part A | | | | |
| Water | | 40 | | |
| Hydroquinone | 123-31-9 | <10 | Xn | 40, 43,68 |
| Potassium hydroxide | 1310-58-3 | <1 | | |