Movix Pro
Celtic SMR Ltd is pleased to announce
the UK launch of its new range of motorised mobiles,the MOVIX Pro. The
mobiles come in a range of power options,from 16 to 50 kW, and so
can be matched to individual hospital requirements. The units are
ergonomically designed for ease of use,allowing effortless movements
with finger tip control.
The compact design and high degree of manoeuverability,enables the unit
to easily negotiate the restricted spaces in busy wards,for bedside
positioning,thus maximising patient and operator convenience. The MOVIX
Pro are built with the latest 3rd generation high frequency
technology,and are fully micro processor controlled.The high power
outputs of the units enables exposure times as short as 0.001sec. to be
made,for paediatric and intensive care applications.
Ergonomic Design
The ergonomically designed operator console enables kV,mA and time to
be adjusted individually or as kV and mAs,or as kV alone. The APR
facility has a storage of 534 images and comes as
standard.Connection to Bucky systems and AEC chambers are
optional.
Movement
The unit has been designed specifically for ease of use,to provide
effortless movements with finger tip control.The arm rotation and
extension,and all vertical movements are locked with electromagnetic
brakes allowing all the positioning angles for standard and specialised
exposures to be made of patients in the standing ,sitting or
lying position.
Mobility
The smooth action of the electric drive enables it to climb inclines in
hospitals.Safety sensors in the front bumpers automatically stops the
unit if any pressure is detected.
Options
40Kw generator
50Kw generator
Mains exposure and battery drive as required.
|
| Model/Specs |
Movix 20 |
Movix 30 |
| Constant Potential kW ratings |
20 |
32 |
| KVp Range in 1 kVp steps |
40 to 125 |
40 to 150 |
| Accuracy |
± (5 % + 1 kVp) |
± (5 % + 1 kVp) |
| Ma Stations |
10, 12.5, 16, 20, 25, 32, 40, |
10, 12.5, 16, 20, 25, 32, 40, |
| |
50, 64, 80, 100, 125, 160, |
50, 64, 80, 100, 125, 160, |
| |
200, 250, 320 |
200, 250, 320, 400, 500 |
| Accuracy |
± (5 % + 1 mA) |
± (5 % + 1 mA) |
| Exposure time range |
0.001 - 8 seconds |
0.001 - 8 seconds |
| Accuracy |
± (2 % + 0.1 ms) |
± (2 % + 0.1 ms) |
| mAs range |
0.1 - 500 mAs |
0.1 - 500 mAs |
| Operation independent from mains supply |
Standard |
Standard |
| Batteries Capacity at full charge |
Up to 180 exposures of 160 mAs (i.e 70
kVp, 320 mA, 0.5 sec) |
|
| (maximum charge after 4 hours) |
can be made with 1 minute interval
between exposures |
|
| Collimator manual |
Standard |
Standard |
| Anatomical programmer |
534 views |
534 views |
| Automatic exposure control |
Optional |
Optional |
| Connection for bucky |
Standard |
Standard |
| Remote wireless infrared hand-switch |
Optional |
Optional |
| Line voltage range and phases |
100 to 240 VAC single phase +/- 10% |
|
| |
|
|
| X-Ray Tube (rotating Anode) |
|
|
| Focal spots |
0.3 / 1.0 |
0.3 / 1.0 |
| KHU /kVp |
140 / 150 |
140 / 150 |
| Target angle |
12° |
12° |
| Optional tube |
|
|
| Focal spots |
|
|
| NA |
0.6/1.2 |
|
| KHU /kVp |
NA |
300 / 150 |
| Target Angle |
NA |
12° |
| Weight |
438 Kg |
438 Kg |
| |
|
|
| Optional exposure control and ion chamber |
|
|
| Optional remote wireless infrared X-ray
hand switch |
|
|
| Optional 0,6/1,2 mm- 300 kHU – 150 kV
X-ray tube instead of standard one. |
|
|
|
|